Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.689
Filtrar
1.
J Orthop Surg Res ; 19(1): 185, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38491520

RESUMO

INTRODUCTION: When needed operative treatment of sacral fractures is mostly performed with percutaneous iliosacral screw fixation. The advantage of navigation in insertion of pedicle screws already could be shown by former investigations. The aim of this investigation was now to analyze which influence iliosacral screw placement guided by navigation has on duration of surgery, radiation exposure and accuracy of screw placement compared to the technique guided by fluoroscopy. METHODS: 68 Consecutive patients with sacral fractures who have been treated by iliosacral screws were inclouded. Overall, 85 screws have been implanted in these patients. Beside of demographic data the duration of surgery, duration of radiation, dose of radiation and accuracy of screw placement were analyzed. RESULTS: When iliosacral screw placement was guided by navigation instead of fluoroscopy the dose of radiation per inserted screw (155.0 cGy*cm2 vs. 469.4 cGy*cm2 p < 0.0001) as well as the duration of radiation use (84.8 s vs. 147.5 s p < 0.0001) were significantly lower. The use of navigation lead to a significant reduction of duration of surgery (39.0 min vs. 60.1 min p < 0.01). The placement of the screws showed a significantly higher accuracy when performed by navigation (0 misplaced screws vs 6 misplaced screws-p < 0.0001). CONCLUSION: Based on these results minimal invasive iliosacral screw placement guided by navigation seems to be a safe procedure, which leads to a reduced exposure to radiation for the patient and the surgeon, a reduced duration of surgery as well as a higher accuracy of screw placement.


Assuntos
Fraturas Ósseas , Parafusos Pediculares , Fraturas da Coluna Vertebral , Cirurgia Assistida por Computador , Humanos , Ílio/diagnóstico por imagem , Ílio/cirurgia , Ílio/lesões , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Cirurgia Assistida por Computador/métodos , Fixação Interna de Fraturas/métodos , Fluoroscopia/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia
2.
Int J Implant Dent ; 10(1): 8, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334913

RESUMO

PURPOSE: Reconstruction with vascularized bone grafts after ablative surgery and subsequent dental rehabilitation with implants is often challenging; however, it helps improve the patient's quality of life. This retrospective case-control study aimed to determine the implant survival/success rates in different vascularized bone grafts and potential risk factors. METHODS: Only patients who received implants in free vascularized bone grafts between 2012 and 2020 were included. The free flap donor sites were the fibula, iliac crest, and scapula. The prosthetic restoration had to be completed, and the observation period had to be over one year after implantation. Implant success was defined according to the Health Scale for Dental Implants criteria. RESULTS: Sixty-two patients with 227 implants were included. The implant survival rate was 86.3% after an average of 48.7 months. The causes of implant loss were peri-implantitis (n = 24), insufficient osseointegration (n = 1), removal due to tumor recurrence (n = 1), and osteoradionecrosis (n = 5). Of all implants, 52.4% were classified as successful, 19.8% as compromised, and 27.8% as failed. Removal of osteosynthesis material prior to or concurrent with implant placement resulted in significantly better implant success than material not removed (p = 0.035). Localization of the graft in the mandibular region was associated with a significantly better implant survival (p = 0.034) and success (p = 0.002), also a higher Karnofsky Performance Status Scale score with better implant survival (p = 0.014). CONCLUSION: Implants placed in vascularized grafts showed acceptable survival rates despite the potential risk factors often present in these patient groups. However, peri-implantitis remains a challenge.


Assuntos
Implantes Dentários , Retalhos de Tecido Biológico , Peri-Implantite , Humanos , Retalhos de Tecido Biológico/transplante , Estudos Retrospectivos , Implantes Dentários/efeitos adversos , Estudos de Casos e Controles , Fíbula/transplante , Ílio/cirurgia , Qualidade de Vida , Escápula/cirurgia
3.
Injury ; 55(3): 111378, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38309085

RESUMO

INTRODUCTION: Spinopelvic dissociation (SPD) is a severe injury characterized by a discontinuity between the spine and the bony pelvis consisting of a bilateral longitudinal sacral fracture, most of the times through sacral neuroforamen, and a horizontal fracture, usually through the S1 or S2 body. The introduction of the concept of triangular osteosynthesis has shown to be an advance in the stability of spinopelvic fixation (SPF). However, a controversy exists as to whether the spinal fixation should reach up to L4 and, if so, it should be combined with transiliac-transsacral screws (TTS). OBJECTIVE: The purpose of this study is to compare the biomechanical behavior in the laboratory of four different osteosynthesis constructs for SPD, including spinopelvic fixation of L5 versus L4 and L5; along with or without TTS in both cases. MATERIAL AND METHODS: By means of a formerly described method by the authors, an unstable standardized H-type sacral fracture in twenty synthetic replicas of a male pelvis articulated to the lumbar spine, L1 to sacrum, (Model: 1300, SawbonesTM; Pacific Research Laboratories, Vashon, WA, USA), instrumented with four different techniques, were mechanically tested. We made 4 different constructs in 5 specimen samples for each construct. Groups: Group 1. Instrumentation of the L5-Iliac bones with TTS. Group 2. Instrumentation of the L4-L5-Iliac bones with TTS. Group 3. Instrumentation of L5-Iliac bones without TTS. Group 4: Instrumentation of L4-L5-Iliac bones without TTS. RESULTS AND CONCLUSIONS: According to our results, it can be concluded that in SPD, better stability is obtained when proximal fixation is only up to L5, without including L4 (alternative hypothesis), the addition of transiliac-transsacral fixations is essential.


Assuntos
Fraturas Ósseas , Fraturas da Coluna Vertebral , Masculino , Humanos , Parafusos Ósseos , Ílio/cirurgia , Fraturas Ósseas/cirurgia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Fixação Interna de Fraturas/métodos
4.
Orthopedics ; 47(1): e13-e18, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37276441

RESUMO

Transiliac-transsacral screw fixation is widely used to stabilize unstable posterior pelvic ring injuries. Preoperative radiographic assessment of the safe osseous corridor is necessary because the safe space of sacrum is narrower for transiliac-transsacral screw placement than for traditional iliosacral screw placement. However, the radiographic assessment has rarely been studied in the Taiwanese population. We retrospectively analyzed 100 patients with pelvic computed tomography images and divided them into normal and dysmorphic pelvis groups. To determine the safe osseous space, we recorded cross-section area, cross-sectional diameter of the safe zone (CS-szD), and safe zone width on axial view (Ax-szW) in the S1 to S3 segments. The prevalence of dysmorphic pelvis was 48% among all patients. In the S1 segment, no differences were found in the cross-section area and CS-szD been the two groups. However, the Ax-szW was significantly smaller in the dysmorphic pelvis group. In the S2 segment, the cross-section area, CS-szD, and Ax-szW were all significantly larger in the dysmorphic pelvis group. In the S3 segment, the cross-section area and CS-szD of the normal pelvis group were both significantly smaller. No differences were found in the Ax-szW between the two groups. Based on our findings in a Taiwanese population, S1 was the most suitable segment for transiliac-transsacral screw fixation in a normal pelvis, whereas S2, followed by S3, was most suitable in a dysmorphic pelvis. This study offers surgeons information on identifying the optimal sacral segment for transiliac-transsacral screw placement for each pelvic morphology. [Orthopedics. 2024;47(1):e13-e18.].


Assuntos
Ossos Pélvicos , Sacro , Humanos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/anatomia & histologia , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões , Ílio/diagnóstico por imagem , Ílio/cirurgia , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Parafusos Ósseos
5.
Injury ; 55(2): 111191, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37972487

RESUMO

BACKGROUND: Sacral alar-iliac screws (SAISs) have been used for sacroiliac joint and are superiority to traditional sacroiliac screws (SISs) in patients with low bone density. The aim of this study was to investigate the operation safety and biomechanical stability of the SIS, transsacral-transiliac screw (TSTIS), S1AIS and S2AIS in the treatment of sacroiliac joint in simulated models of low bone density. METHODS: CT data from 80 normal pelvic structures were employed to measure the anatomical parameters, including the safety zones of the S1AIS and S2AIS at the insertion point and the trajectory lengths of the SIS, TSTIS, S1AIS and S2AIS. Sixteen synthetic pelvises with simulated osteoporotic bone structure were used to simulate type C Tile lesions and divided into 4 groups with an anterior plate and posterior fixation using one of the following: 1) one SIS on each side, 2) one TSTIS fixing both sides, 3) one S1AIS on each side, or 4) one S2AIS on each side. The stiffness and maximum load of the specimens were analyzed using a biomechanical machine under vertical loading. RESULTS: The safety zone of S1AIS was larger than that of S2AIS (p < 0.05). The TSTIS had the largest trajectory length, followed by the S1AIS and S2AIS, and the SIS had the smallest trajectory length (p < 0.05). However, the lengths of the TSTIS (26.1 ± 1.7 mm) and SIS (27.8 ± 1.8 mm) trajectories on the short side (the iliac side) were smaller than those of S1AIS (40.4 ± 3.8 mm) and S2AIS (39.1 ± 3.8 mm), thus indicating significant differences (p < 0.05). The stiffness and maximum load of S1AIS and S2AIS were similar and the greatest, followed by TSTIS and SIS (p < 0.05). CONCLUSION: The stability of S1AIS and S2AIS is similar, both stronger than that of SIS and TSTIS, which have shorter lengths of the screw trajectories on the ilium side. However, the safety zone of S2AIS at the insertion point is smaller than that of S1AIS. Therefore, considering both safety and stability, S1AIS is the preferred choice for fixation of sacroiliac joint dislocation in simulated models of low bone density.


Assuntos
Doenças Ósseas Metabólicas , Luxações Articulares , Humanos , Ílio/cirurgia , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/cirurgia , Parafusos Ósseos , Sacro/cirurgia , Fixação Interna de Fraturas , Fenômenos Biomecânicos
6.
J Bone Joint Surg Am ; 106(2): 129-137, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-37992198

RESUMO

BACKGROUND: Sacral dysmorphism is not uncommon and complicates S1 iliosacral screw placement partially because of the difficulty of determining the starting point accurately on the sacral lateral view. We propose a method of specifying the starting point. METHODS: The starting point for the S1 iliosacral screw into the dysmorphic sacrum was specifically set at a point where the ossification of the S1/S2 intervertebral disc (OSID) intersected the posterior vertebral cortical line (PVCL) on the sacral lateral view, followed by guidewire manipulation and screw placement on the pelvic outlet and inlet views. Computer-simulated virtual surgical procedures based on pelvic computed tomography (CT) data on 95 dysmorphic sacra were performed to determine whether the starting point was below the iliac cortical density (ICD) and in the S1 oblique osseous corridor and to evaluate the accuracy of screw placement (with 1 screw being used, in the left hemipelvis). Surgical procedures on 17 patients were performed to verify the visibility of the OSID and PVCL, to check the location of the starting point relative to the ICD, and to validate the screw placement safety as demonstrated with postoperative CT scans. RESULTS: In the virtual surgical procedures, the starting point was consistently below the ICD and in the oblique osseous corridor in all patients and all screws were Grade 1. In the clinical surgical procedures, the OSID and PVCL were consistently visible and the starting point was always below the ICD in all patients; overall, 21 S1 iliosacral screws were placed in these 17 patients without malpositioning or iatrogenic injury. CONCLUSIONS: On the lateral view of the dysmorphic sacrum, the OSID and PVCL are visible and intersect at a point that is consistently below the ICD and in the oblique osseous corridor, and thus they can be used to identify the starting point. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Ossos Pélvicos/cirurgia , Ílio/diagnóstico por imagem , Ílio/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Fraturas Ósseas/cirurgia
7.
Spine Deform ; 12(2): 501-505, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37882967

RESUMO

PURPOSE: To present a case of a pseudoaneurysm of a branch of the left superior gluteal artery (SGA) secondary to lateral wall perforation from an iliac screw and its subsequent evaluation and management. METHODS: Case report. RESULTS: A 67-year-old female with a history of degenerative flatback and scoliosis and pathological fractures of T12 and L1 secondary to osteodisciitis underwent a single0stage L5-S1 ALIF and T9-pelvis posterior instrumented fusion with bilateral dual iliac screw fixation, revision T11-S1 decompression, and T12 and L1 irrigation and debridement and partial corpectomies. During the operation, non-pulsatile bleeding was encountered after creating an initial trajectory for the more proximal of the two left iliac screws. While the initial post-operative course was benign, the patient was readmitted for hypotension and anemia. Computed tomography of the abdomen/pelvis demonstrated a pseudoaneurysm (2.3 cm × 2.1 cm × 2.3 cm) of a branch of the left SGA. Diagnostic angiogram confirmed a pseudoaneurysm off of one of the branches of the left SGA. Endovascular embolization using multiple coils resulted in a complete cessation of blood flow in the pseudoaneurysm. At 2 years follow-up, no symptoms suggestive of recurrence of the pseudoaneurysm were reported. CONCLUSIONS: A pseudoaneurysm of a branch of the left superior gluteal artery as a result of lateral wall perforation from an aberrantly placed iliac screw during an adult spinal deformity operation involving dual screw pelvic fixation is reported. Prompt recognition, multidisciplinary collaboration, and appropriate intervention were key in achieving a successful outcome and preventing further morbidity.


Assuntos
Falso Aneurisma , Idoso , Feminino , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Artérias , Parafusos Ósseos , Ílio/cirurgia , Pelve
8.
Oper Neurosurg (Hagerstown) ; 26(1): 92-95, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38099693

RESUMO

BACKGROUND AND IMPORTANCE: With the exception of the 3 classic shunt placement options (ventriculoperitoneal, ventriculopleural, and ventriculoatrial), surgically feasible alternative sites for distal catheter placement remain limited and often require the assistance of an access surgeon. Tubbs et al suggested the possibility of intraosseous cerebrospinal fluid diversion in the ilium, noting that ilium infusion in cadaveric specimens was possible without the development of body edema or fluid overflow. Since this publication, limited case reports have been published on the success of ventriculo-ilium (VI) shunt placement. Here, we describe the technique used for successful VI shunt placement in 2 adult patients. CLINICAL PRESENTATION: Here, we describe 2 patients with differing etiologies of hydrocephalus (obstructive and nonobstructive) and complex medical and surgical problems precluding traditional distal shunt termini. Both patients underwent successful placement of a VI shunt with distal catheter placement into the right iliac crest using a small right-angle connector and small cranial fixation plate to prevent backout of the catheter. DISCUSSION AND CONCLUSION: We report the first demonstration of successful placement of a VI shunt in 2 adult patients with evidence of shunt functionality and improved neurological outcome. We propose that the placement of a VI shunt is an easy and viable option when more traditional shunt methods are not available for use.


Assuntos
Hidrocefalia , Derivação Ventriculoperitoneal , Adulto , Humanos , Derivação Ventriculoperitoneal/métodos , Ílio/cirurgia , Hidrocefalia/etiologia , Hidrocefalia/cirurgia , Derivações do Líquido Cefalorraquidiano/métodos , Crânio/cirurgia
9.
Injury ; 54 Suppl 6: 110837, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143137

RESUMO

INTRODUCTION: Isolated fractures of the iliac wing are a rare injury, usually occurring in high-energy trauma, and are associated with other non-musculoskeletal and soft tissue injuries that could compromise the patient's life. Surgical indications are unclear, and there is limited information on the most frequent fracture patterns. METHODS: A descriptive multicenter case series study of isolated fractures of the iliac wing treated surgically in three referral trauma hospitals in Latin America. The different fracture patterns are described, the "iliac ring" concept is proposed, and a classification is made. RESULTS: Twenty-eight patients were included; 24 were male, the median age was 31 years RIQ (24-46), the most frequent trauma mechanism was a traffic accident, and in 14 patients, the ISS >16. The most frequent associated injury was to the appendicular skeleton at another level in 13 patients. In the new classification, according to the number of fragments, 11 patients were classified as type A (1 fragment), ten patients as type B (two fragments), and seven patients as type C (three or more fragments). The most compromised anatomical area was the crest and anterosuperior iliac spines in 26 patients, followed by the fossa and anteroinferior iliac spine in 17 and 8 patients, respectively. DISCUSSION: The patterns of isolated fractures of the iliac wing allow the identification of three types of fractures. Identifying these patterns can help the surgeon decide to perform surgery in these scenarios and choose the fixation technique according to the number and location of the fragments.


Assuntos
Fraturas Ósseas , Luxações Articulares , Lesões do Pescoço , Ossos Pélvicos , Fraturas da Coluna Vertebral , Humanos , Masculino , Adulto , Feminino , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Ílio/cirurgia , Luxações Articulares/terapia , Ossos Pélvicos/lesões , Fixação Interna de Fraturas/métodos
10.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(11): 1418-1422, 2023 Nov 15.
Artigo em Chinês | MEDLINE | ID: mdl-37987054

RESUMO

Objective: To conduct anatomical study on the iliac crest chimeric tissue flap and summarize its effectiveness of clinical application in repairing limb wounds. Methods: Latex perfusion and anatomical study were performed on 6 fresh adult cadaver specimens with 12 sides, to observe the initial location, distribution, quantity, and direction of the common circumflexa iliac artery, the deep circumflexa iliac artery, and the superficial circumflexa iliac artery, and to measure their initial external diameter. Between December 2020 and September 2022, the iliac crest chimeric tissue flap repair was performed on 5 patients with soft tissue of limbs and bone defects. There were 3 males and 2 females, with an average age of 46 years (range, 23-60 years). Among them, there were 3 cases of radii and skin soft tissue defects and 2 cases of tibia and skin soft tissue defects. The length of bone defects was 4-8 cm and the area of skin soft tissue defects ranged from 9 cm×5 cm to 15 cm×6 cm. The length of the iliac flap was 4-8 cm and the area of skin flap ranged from 12.0 cm×5.5 cm to 16.0 cm×8.0 cm. The donor sites were directly sutured. Results: Anatomical studies showed that there were 10 common circumflex iliac arteries in 5 specimens, which originated from the lateral or posterolateral side of the transition between the external iliac artery and the femoral artery, with a length of 1.2-1.6 cm and an initial external diameter of 0.8-1.4 mm. In 1 specimen without common circumflexa iliac artery, the superficial and deep circumflex iliac arteries originated from the external iliac artery and the femoral artery, respectively, while the rest originated from the common circumflex iliac artery. The length of superficial circumflex iliac artery was 4.6-6.7 cm, and the initial external diameter was 0.4-0.8 mm. There were 3-6 perforator vessels along the way. The length of deep circumflex iliac artery was 7.8-9.2 cm, and the initial external diameter was 0.5-0.7 mm. There were 3-5 muscular branches, 4-6 periosteal branches, and 2-3 musculocutaneous branches along the way. Based on the anatomical observation results, all iliac crest chimeric tissue flaps were successfully resected and survived after operation. The wounds at recipient and donor sites healed by first intention. All patients were followed up 8-24 months, with an average of 12 months. The tissue flap has good appearance and soft texture. X-ray film reexamination showed that all the osteotomy healed, and no obvious bone resorption was observed during follow-up. Conclusion: The common circumflex iliac artery, deep circumflex iliac artery, and superficial circumflex iliac artery were anatomically constant, and it was safe and reliable to use iliac crest chimeric tissue flap in repairing the soft tissue and bone defects of limbs.


Assuntos
Retalho Perfurante , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Adulto , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Ílio/cirurgia , Retalho Perfurante/irrigação sanguínea , Transplante de Pele/métodos , Extremidade Inferior/cirurgia , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento
11.
J Evid Based Dent Pract ; 23(4): 101927, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38035902

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Effect of autogenous bone graft site on dental implant survival and donor site complications: A systematic review and meta-analysis. J Evid Based Dent Pract. 2022 Sep;22(3):101731.           SOURCE OF FUNDING: Not reported. TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Humanos , Transplante Ósseo , Implantação Dentária Endóssea , Seguimentos , Ílio/cirurgia , Taxa de Sobrevida , Resultado do Tratamento , Revisões Sistemáticas como Assunto , Metanálise como Assunto
12.
Zhongguo Gu Shang ; 36(11): 1058-64, 2023 Nov 25.
Artigo em Chinês | MEDLINE | ID: mdl-38012875

RESUMO

OBJECTIVE: To evaluate the feasibility of S2 alar iliac screw insertion in Chinese children using computerized three-dimension reconstruction and simulated screw placement technique, and to optimize the measurement of screw parameters. METHODS: A total of 83 pelvic CT data of children who underwent pelvic CT scan December 2018 to December 2020 were retrospectively analyzed, excluding fractures, deformities, and tumors. There were 44 boys and 39 girls, with an average age of (10.66±3.52) years, and were divided into 4 groups based on age (group A:5 to 7 years old;group B:8 to 10 years old;group C:11-13 years old;group D:14 to 16 years old). The original CT data obtained were imported into Mimics software, and the bony structure of the pelvis was reconstructed, and the maximum and minimum cranial angles of the screws were simulated in the three-dimensional view with the placement of 6.5 mm diameter S2 alar iliac screws. Subsequently, the coronal angle, sagittal angle, transverse angle, total length of the screw, length of the screw in the sacrum, width of the iliac, and distance of the entry point from the skin were measured in 3-Matic software at the maximum and minimum head tilt angles, respectively. The differences among the screw parameters of S2 alar iliac screws in children of different ages and the differences between gender and side were compared and analyzed. RESULTS: In all 83 children, 6.5 mm diameter S2 iliac screws could be placed. There was no significant difference between the side of each screw placement parameter. The 5 to 7 years old children had a significantly smaller screw coronal angle than other age groups, but in the screw sagittal angle, the difference was more mixed. The 5 to 7 years old children could obtain a larger angle at the maximum head tilt angle of the screw, but at the minimum cranial angle, the larger angle was obtained in the age group of 11 to 13 years old. There were no significant differences among the age groups. The coronal angle and sagittal angle under maximum cephalic angle and minimum cranial angle of 5 to 7 years old male were (40.91±2.91)° and (51.85±3.75)° respectively, which were significantly greater than in female. The coronal angle under minimum cranial angle was significantly greater in girls aged 8-10 years old than in boys. For the remaining screw placement angle parameters, there were no significant differences between gender. The differences in the minimum iliac width, the screw length, and the length of the sacral screws showed an increasing trend with age in all age groups. The distance from the screw entry point to the skin in boys were significantly smaller than that of girls. The minimum width of the iliac in boys at 14 to 16 years of age were significantly wider than that in girls at the same stage. In contrast, in girls aged 5 to 7 years and 11 to 13 years, the screw length was significantly longer than that of boys at the same stage. CONCLUSION: The pelvis of children aged 5 to 16 years can safely accommodate the placement of 6.5 mm diameter S2 alar iliac screws, but the bony structures of the pelvis are developing and growing in children, precise assessment is needed to plan a reasonable screw trajectory and select the appropriate screw length.


Assuntos
Ílio , Fusão Vertebral , Humanos , Masculino , Feminino , Criança , Adolescente , Pré-Escolar , Ílio/cirurgia , Estudos Retrospectivos , Estudos de Viabilidade , Parafusos Ósseos , Pelve , Sacro/cirurgia , Fusão Vertebral/métodos
13.
JBJS Case Connect ; 13(4)2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37917873

RESUMO

CASE: We present a case of a 54-year-old man with atraumatic, U-type sacral insufficiency and L5 compression fractures leading to spinopelvic dissociation, inability to ambulate, and bowel/bladder compromise. The patient underwent L3-4 percutaneous pedicle screw fixation with bilateral iliac bolts and percutaneous iliosacral screw fixation. Postoperatively, the patient had return of bowel/bladder function and independent ambulation at 2.5 years. CONCLUSION: Atraumatic spinopelvic dissociation is an underappreciated pathology in older patients. Here, we describe the result of our preferred treatment strategy, triangular osteosynthesis, to preserve function and independence. Despite optimal, prompt treatment, these injuries pose a difficult rehabilitation process for patients.


Assuntos
Fraturas de Estresse , Fraturas da Coluna Vertebral , Masculino , Humanos , Idoso , Pessoa de Meia-Idade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas de Estresse/diagnóstico por imagem , Fraturas de Estresse/cirurgia , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Fixação Interna de Fraturas/métodos , Ílio/cirurgia
14.
BMC Surg ; 23(1): 301, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37794394

RESUMO

BACKGROUND: To investigate the ideal trajectory for the S2AI screw and to clinically validate its safety feasibility. METHODS: The 3D model was reconstructed from CT data of the pelvis of 30 selected adults, and the 3D coordinate system was established with the first sacral superior endplate as the horizontal plane. A set of cutting planes was made at 3 mm intervals in the coronal plane, and the cross-sectional internal tangent circles were divided in the target area. Using the linear fitting function, the axis of 90 mm length was calculated by the least squares method for each inner tangent circle center. The diameter of the axis is gradually increased until the first contact with the cortex, and the cylindrical model is the ideal screw trajectory. The intersection of the axis and the dorsal cortex is the screw placement point, which is located by Horizon Distance (HD) and Vertical Distance (VD); the diameter of the screw trajectory (d) is the diameter of the cylindrical model; the direction of the screw trajectory is determined by Sagittal Angle (SA) and Transverse Angle (TA). The screw trajectory orientation is determined by Sagittal Angle (SA) and Transverse Angle (TA). Based on the ideal screw trajectory, the 3D printed surgical guide and freehand techniques were used to verify its safety feasibility, respectively. RESULTS: The screw placement points [HD (4.7 ± 1.0) mm, VD (19.7 ± 1.9) mm], screw placement directions [SA (31.3°±2.3°), TA (42.4°±2.3°)], and screw dimensions for the ideal screw trajectory of the S2AI were combined for analysis. (L is 90 mm, d is 13.2 ± 1.4 mm). The S2AI screw superiority rate [96.6% (56/58)] and reasonable rate [100%] were higher in the guide group than in the freehand group [90.0% (63/70), 97.1% (68/70)], but the differences were not statistically significant (P > 0.05). Although screws invaded the cortex in both groups, there were no associated adverse events in either group. CONCLUSION: The S2AI screw-based ideal trajectory placement is a safe, feasible and accurate method of screw placement.


Assuntos
Ílio , Fusão Vertebral , Adulto , Humanos , Estudos Transversais , Ílio/cirurgia , Parafusos Ósseos , Sacro/cirurgia , Pelve , Fusão Vertebral/métodos
15.
Head Neck ; 45(10): 2544-2554, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37530710

RESUMO

BACKGROUND: The purpose of this study was to investigate the effect of anterior superior iliac spine (ASIS) preservation on donor site morbidity and function after harvesting a vascularized iliac bone flap (VIBF). METHODS: Patients who underwent jaws reconstruction with VIBF were divided into a maintaining the anterior superior iliac spine (MASIS) group and a not maintaining the anterior superior iliac spine (NMASIS) group. Pain, tenderness, sensory deficit, gait disturbance, and function of the donor site were evaluated before and after the operation. RESULTS: Thirty-three patients were included in this study, of which 18 were in the MASIS group. The incidence of sensory deficit in the MASIS group was significantly lower than that in the NMASIS group (50.0% vs. 86.7%, p = 0.010). Pain, tenderness, gait disturbance, and function did not differ statistically between the two groups. CONCLUSION: Except for sensory deficit, ASIS preservation has minimal impact on donor site morbidity and function.


Assuntos
Ílio , Retalhos Cirúrgicos , Humanos , Morbidade , Incidência , Ílio/cirurgia , Dor , Transplante Ósseo/efeitos adversos
16.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(4): 324-333, Jun-Jul. 2023. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-222533

RESUMO

Objetivo: Comparar in vivo la capacidad de formación ósea de dos tipos de biomateriales diseñados como sustitutivos óseos respecto a autoinjerto de cresta iliaca, uno basado en carbonatohidroxiapatita y otro en vidrio mesoporoso bioactivo. Material y método: Estudio experimental compuesto por 14 conejos de Nueva Zelanda hembras adultas donde se realizó un defecto crítico en hueso radio. La muestra fue dividida en cuatro grupos: defecto sin material, con autoinjerto de cresta iliaca, con soporte de carbonatohidroxiapatita y con soporte de vidrio mesoporoso bioactivo. Se realizaron estudios seriados de radiología simple a las 2, 4, 6 y 12 semanas y estudio de micro-TC a eutanasia a las 6 y 12 semanas. Resultados: En el estudio de radiología simple, el grupo de autoinjerto mostró las mayores puntuaciones de formación ósea (7,5 puntos). Ambos grupos de biomateriales presentaron formación ósea similar (5,3 y 6 puntos, respectivamente) y mayor al defecto sin material (4 puntos), pero siempre menor que el grupo de autoinjerto. Los resultados del estudio de micro-TC mostraron el mayor volumen de hueso en el área de estudio en el grupo de autoinjerto. Los grupos con sustitutivos óseos presentaron mayor volumen de hueso que el grupo sin material, pero siempre menor que en el grupo de autoinjerto. Conclusiones: Ambos soportes parecen favorecer la formación ósea pero no son capaces de reproducir las características del autoinjerto. Por sus diferentes características macroscópicas cada uno podría ser adecuado para un tipo diferente de defecto.(AU)


Aim: Compare bone formation capacity in vivo of two types of biomaterials designed as bone substitutes with respect to iliac crest autograft, one based on carbonate hydroxyapatites and the other one on bioactive mesoporous glass. Materials and methods: Experimental study consisting on 14 adult female New Zeland rabbits where a critical defect was made in the rabbit radius bone. The sample was divided into four groups: defect without material, with iliac crest autograft, with carbonatehydroxyapatite support, and with bioactive mesoporous glass support. Serial X-ray studies were carried out at 2, 4, 6 and 12 weeks and a microCT study at euthanasia at 6 and 12 weeks. Results: In the X-ray study, autograft group showed the highest bone formation scores. Both groups of biomaterials presented bone formation similar and greater than the defect without material, but always less than in the autograft group. The results of the microCT study showed the largest bone volume in the study area in the autograft group. The groups with bone substitutes presented greater bone volume than the group without material but always less than in the autograft group. Conclusion: Both supports seem to promote bone formation but are not capable of reproducing the characteristics of autograft. Due to their different macroscopic characteristics, each one could be suitable for a different type of defect.(AU)


Assuntos
Animais , Osteogênese , Materiais Biocompatíveis , Transplante Autólogo , Ílio/cirurgia , Coelhos/anatomia & histologia , Coelhos/cirurgia , Nova Zelândia , Radiografia , Durapatita , Regeneração Óssea
17.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(4): T324-T333, Jun-Jul. 2023. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-222534

RESUMO

Objetivo: Comparar in vivo la capacidad de formación ósea de dos tipos de biomateriales diseñados como sustitutivos óseos respecto a autoinjerto de cresta iliaca, uno basado en carbonatohidroxiapatita y otro en vidrio mesoporoso bioactivo. Material y método: Estudio experimental compuesto por 14 conejos de Nueva Zelanda hembras adultas donde se realizó un defecto crítico en hueso radio. La muestra fue dividida en cuatro grupos: defecto sin material, con autoinjerto de cresta iliaca, con soporte de carbonatohidroxiapatita y con soporte de vidrio mesoporoso bioactivo. Se realizaron estudios seriados de radiología simple a las 2, 4, 6 y 12 semanas y estudio de micro-TC a eutanasia a las 6 y 12 semanas. Resultados: En el estudio de radiología simple, el grupo de autoinjerto mostró las mayores puntuaciones de formación ósea (7,5 puntos). Ambos grupos de biomateriales presentaron formación ósea similar (5,3 y 6 puntos, respectivamente) y mayor al defecto sin material (4 puntos), pero siempre menor que el grupo de autoinjerto. Los resultados del estudio de micro-TC mostraron el mayor volumen de hueso en el área de estudio en el grupo de autoinjerto. Los grupos con sustitutivos óseos presentaron mayor volumen de hueso que el grupo sin material, pero siempre menor que en el grupo de autoinjerto. Conclusiones: Ambos soportes parecen favorecer la formación ósea pero no son capaces de reproducir las características del autoinjerto. Por sus diferentes características macroscópicas cada uno podría ser adecuado para un tipo diferente de defecto.(AU)


Aim: Compare bone formation capacity in vivo of two types of biomaterials designed as bone substitutes with respect to iliac crest autograft, one based on carbonate hydroxyapatites and the other one on bioactive mesoporous glass. Materials and methods: Experimental study consisting on 14 adult female New Zeland rabbits where a critical defect was made in the rabbit radius bone. The sample was divided into four groups: defect without material, with iliac crest autograft, with carbonatehydroxyapatite support, and with bioactive mesoporous glass support. Serial X-ray studies were carried out at 2, 4, 6 and 12 weeks and a microCT study at euthanasia at 6 and 12 weeks. Results: In the X-ray study, autograft group showed the highest bone formation scores. Both groups of biomaterials presented bone formation similar and greater than the defect without material, but always less than in the autograft group. The results of the microCT study showed the largest bone volume in the study area in the autograft group. The groups with bone substitutes presented greater bone volume than the group without material but always less than in the autograft group. Conclusion: Both supports seem to promote bone formation but are not capable of reproducing the characteristics of autograft. Due to their different macroscopic characteristics, each one could be suitable for a different type of defect.(AU)


Assuntos
Animais , Osteogênese , Materiais Biocompatíveis , Transplante Autólogo , Ílio/cirurgia , Coelhos/anatomia & histologia , Coelhos/cirurgia , Nova Zelândia , Radiografia , Durapatita , Regeneração Óssea
18.
Acta Neurochir (Wien) ; 165(9): 2607-2614, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37458861

RESUMO

PURPOSE: The iliac fixation (IF) through the S2 ala permits the minimization of implant prominence and tissue dissection. An alternative to this technique is the anatomic iliac screw fixation (AI), which considers the perpendicular axis to the narrowest width of the ileum and the width of the screw. The morphological accuracy of the iliac screw insertion of two low profile iliac fixation (IF) techniques is investigated in this study. METHODS: Twenty-nine patients operated on via low profile IF technique were divided into two groups, those treated using 28 screws with the starting point at S2, and those treated with 30 AI entry point. Radiological parameters (Tsv-angle, Sag-Angle, Max-length, sacral-distance, iliac-width, S2-midline, skin-distance, iliac-wing, and PSIS distance) and clinical outcomes (early and clinic complications) were evaluated by two blinded expert radiologists, and the results were compared in both groups with the real trajectory of the screws placed. RESULTS: Differences between ideal and real trajectories were observed in 6 of the 9 evaluated parameters in the S2AI group. In the AI group, these trajectories were similar, except for TSV-Angle, Max-length, Iliac-width, and distance to iliac-wing parameters. Moreover, compared with S2AI, AI provided better adaptation to the pelvic morphology in all parameters, except for sagittal plane angulation, skin distance, and iliac width. CONCLUSIONS: AI ensures the advantages of low profile pelvic fixation like S2AI, with a starting point in line with S1 pedicle anchors and low implant prominence, and moreover adapts better to the morphological features of the pelvis of each individual.


Assuntos
Ílio , Fusão Vertebral , Humanos , Ílio/diagnóstico por imagem , Ílio/cirurgia , Pelve , Sacro/diagnóstico por imagem , Sacro/cirurgia , Radiografia , Tomografia Computadorizada por Raios X , Fusão Vertebral/métodos
20.
Spine J ; 23(12): 1928-1934, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37479142

RESUMO

BACKGROUND CONTEXT: Lumbosacral fusion supplemented with sacropelvic fusion has recently been increasingly employed for correcting spinal deformity and is associated with lower incidence of pseudarthrosis and implant failure. To date, few studies have evaluated anatomical parameters and technical feasibility between different entry points for S2 alar-iliac screws. PURPOSE: To compare anatomical parameters and technical feasibility of two entry points for the S2 alar-iliac screw (S2AIS) in a Japanese cohort using three-dimensional (3D) computed tomography (CT). STUDY DESIGN/SETTING: Retrospective cohort study. PATIENT SAMPLE: Fifteen men and 15 women aged 50-79 years who underwent pelvic CT at our hospital in 2013. OUTCOME MEASURES: Screw length, lateral angulation, caudal angulation, angle range, distance from the entry point to the sacroiliac joint, distance from the S2AIS to the acetabular roof, distance from the S2AIS to the sciatic notch, and insertion difficulty. METHODS: We used 30 pelvic CT images (15 men and 15 women). We selected two entry points from previous studies: one was 1 mm distal and 1 mm lateral to the S1 dorsal foramen (A group) and the other was the midpoint between the S1 and S2 dorsal foramen (B group). We resliced the plane in which the pelvis was sectioned obliquely from these entry points to the anterior inferior iliac spine in the sagittal plane. We placed the shortest and longest virtual S2AISs bilaterally in this plane using a 4-mm margin. We measured screw length, lateral angulation, caudal angulation, angle range, distance from the entry point to the sacroiliac joint, distance from the S2AIS to the acetabular roof, distance from the S2AIS to the sciatic notch, and insertion difficulty. These measurements were compared between Groups A and B. RESULTS: In group A, the angle in the sagittal plane was significantly smaller and the distance from the entry point to the sciatic notch was significantly longer than in group B. Group B demonstrated a significantly longer screw length, longer distance from the entry point to the sacroiliac joint, and longer distance from the entry point to the acetabular roof than group A. The rate of insertion difficulty of S2AIS was much higher in group A. CONCLUSIONS: Insertion of S2AIS from the midpoint between the S1 and S2 dorsal foramen compared with the entry at distal and lateral to S1 foramen enables insertion of longer screws with low insertion difficulty.


Assuntos
Sacro , Fusão Vertebral , Feminino , Humanos , Masculino , Parafusos Ósseos , População do Leste Asiático , Ílio/diagnóstico por imagem , Ílio/cirurgia , Estudos Retrospectivos , Sacro/cirurgia , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade , Idoso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...